The RPC view_setprop can only be executed by the owner. Use 'crmregister add -database -connection -user ' to set these via the ClearCase command line interface. 345 10/01/10 12:36PM EXEC cleartool: Error: Unable to begin delivery, ClearQuest error. From the msadm_server log: 5/10/2006 6:32:20 AM msadm_server(29113): Error: Operation "vob_ob_replica_oid_to_vobh" failed ("4b1e9977.e1af4406.b4ef.75:cb:34:09:bd:79"): ClearCase object not found. 5/10/2006 6:32:20 AM msadm_server(29113): Error: Unable to get VOB object registry information for replica If the attempted command looked like # ct mktag -view -tag new-view-tag viewstore/new-view-tag.vws it may be necessary to include the extended path information # ct mktag -view -tag new-view-tag -host server-name http://tubee.net/cleartool-error/cleartool-error-unable-to-access-file.html

Error: albd_server must run in the clearcase group clearimport: Error: Newer version in VOB blocks import of version "version". Validate Random Die Tippers What is the difference between perspective distortion and barrel or pincushion distortion? Internal Error detected in "\atria\lib\sum_stream.cxx" line 608. Investigation revealed that there was a checkout trigger running in the VOB in question whose script was located in another VOB that was not currently mounted on Windows. http://www-01.ibm.com/support/docview.wss?uid=swg21123541

If you're sitting inside the correct view no the CLI, the system will understand where to find the activity. If it runs without error but fails to rm the link, try doing an unco on the parent directory and then run the UNIX unlink. HCLNFSD/PCNFSD Error This error occurs when you try to map an exported UNIX drive to the your PC. cleartool: Error: Unable to cancel rebase because another operation is trying to complete.

That is, all versions of all elements always point back to the original in the VOB and behavior is much more predictable. These happen when trying to unmount a VOB that is currently being used. Merge Manager: Error: An error occurred while merging file elements in the target view. OLE exception from "ClearCase.Application.1": Unable to access "extended version path": Invalid argument.

A duplicate file name exists, or the file cannot be found. Depending on the state of the database, certain information can be lost. Review technote 1124574 for more details. http://www-01.ibm.com/support/docview.wss?uid=swg21143201 In this case, you must use the "-host -hpath -gpath" as a set trio of options.

d) Ensure Local Access and Remote Access are checked. 5) Close Component Services. The stream/branch name cannot be the same as the activity. If any activities cannot be relinked with their original ticket, a new ticket is created under the UCMUtilityActivity record type. The user can log into CQ on the same machine.

Or, you can simply wait until the View Profile Tree is idle. Error: "java.io.IOException: Unable to acquire lock to copy area registry. (Lock file is "path\.ccase_wvreg_lockfile". That is, if you checkout a non-selected version from one of the linked elements, you will get the version you expected. See the discussion in "CC group permissions".

Root directory element for component "component" is unavailable. check over here I finally figured out the following: The agent on that server is running under id "bldforge", instead of local system by default. The administrator should be able to remove and add groups at will. See http://www-01.ibm.com/support/docview.wss?uid=swg21127922 for a solution.

These errors occur when attempting to check in a UNIX link that was made into an element. Back to the INDEX. Baselines and such will be out of sync then. his comment is here Go to the view container directory pointed to by the error and create an empty file with the same name.

See the Event Viewer for the error message. Updated: 07/23/13 Version: 7.1.2.4 This error occurred when attempting create a view for a UCM stream. Back to the INDEX.

A subsequent checkin will simply create a new version via a merge with whatever the LATEST version was and the view will go back to selecting the old version it was

This is because the original was apparently owned by somebody else and by doing the clearimport you are telling CC to create an element owned by the other person, which is If not, the replica uuid can be correlated to a vob via the /var/adm/atria/log/scrubber_log or /var/adm/atria/rgy/vob_* files. Instead, use Import -> VOB as Component. Unable to open file "/tmp9999.pmt": permission denied This error message shows up anytime CC tries to write a file to the directory pointed to by the environment variable TMP.

Unfortunately, the lab they were in was running CC 2003, which didn't yet have crmregister and they were only working from the command line. Rmelem on everything in the lost+found directory in the original VOB and rerun the clearexport_ccase the same way, or rerun the clearexport_ccase specifying everything in the original directory with the exception Create a VOB Tag In the case where the VOB tag was removed, and you need to recreate one, execute the cleartool mktag command: cleartool mktag -vob -tag Upon weblink Back to the INDEX.

The fix is unknown. ClearCase albd service did not start. Simply check back in the schema and redo the CQ-enable. That is, you are only allowed to "recommend" baselines that were created in the project.

Related information About vobsvr_contact call failed: RPC: Program unavaila Cross reference information Segment Product Component Platform Version Edition Software Development Rational ClearCase VOB Software Development Rational ClearCase Scheduler Software Development Rational For inexplicable reasons, the share, not the directory itself but the share, had "Change" permissions only for the group of users that needed to create views there. The downside of this is that the original creator and creation date history information are lost. NOTE: Sometimes the "db" database directory cannot be renamed due to files in use.

I want to run the step/command using my id (c999752). Name "stream:id already exists. The memory could not be "read". Even if it's not checked-in (versioned), it is still considered a view-private file and be dealt with using appropriate cleartool commands.

The simple solution for this is for an Adminstrator to give the "SYSTEM" permission to edit the registry.